FC-PSU-240516 POWER SUPPLY UNIT 245 VDC, 16AMANUFACTURE R HONEYWELL China genuine spare parts
Honeywell-China

Genuine List of Honeywell HC900 Card Spare Parts Models from Chinese local suppliers

HC900 Process Control Model Selection Guide System - Legacy Racks MODEL NUMBER 4 I/O Slot Rack 900R04-0001 8 I/O Slot Rack 900R08-0101 12 I/O Slot Rack 900R12-0101 8 Slot Rack -Red. Power 900R08R-0101 12 Slot Rack - Red. Power 900R12R-0101 Redundant Power Status Module 900PSM-0001 Remote I/O Rack I/O Scanner - 2 Port (1 per I/O rack) 900C73R-0100-44 I/O Scanner (for remote rack) 900C53-0244-00 Power Supplies 120/240VAC, 60W Note 7 900P01-0001 120/240VAC, 28W Note 5 & 7 900P02-0001 24Vdc, 60W Note 7 900P24-0001 CPU Assemblies Controller C70 CPU Note 1 & 8 900C72-0144-00 Controller C50 CPU Note 1 & 8 900C52-0244-00 Controller C30 CPU Note 1 & 8 900C32-0244-00 Redundant Controller Rack and CPU Redundant CPU Rack 900RR0-0001 Redundant Controller C70R CPU Note 1 & 8 900C72R-0100-44 Redundant Switch Module 900RSM-0001 I/O Card Selections Analog Input (8 channel) 900A01-0102 Analog Input Hi level (16ch) 900A16-0001 Analog Output, 0 to 20mA, (4 channel) Note 7 900B01-0201 Analog Output, 0 to 20mA, (8 channel) 900B08-0001 Analog Output, 0 to 20mA, (16 channel) 900B16-0001 Digital Input, Contact type, (16 channel) 900G01-0102 Digital Input, 24VDC (16 channel) 900G02-0102 Digital Input, 120/240 VAC, (16 channel) 900G03-0102 Digital In, 120/240 VAC, 125 VDC(16 channel-Isolated) 900G04-0001 Digital Input, 24VDC (32 channel) 900G32-0001 Digital Output, Relays ( 8 channel) 900H01-0102 Digital Output, 24VDC (16 channel) 900H02-0102 Digital Output, 120/240 VAC (8 channel) 900H03-0102 Digital Output, 24VDC (32 channel) 900H32-0001 Pulse/Freq/Quad (4chan, 1Quad) Note 7 900K01-0101 51-51-16U-93 Issue 2 Page 2 of 4 Terminal Blocks, Cables, Jumpers MODEL NUMBER Low VoltageTerminal Block (Euro style) Note 3 900TEK-0001 Low VoltageTerminal Block (Barrier Style) Note 3 900TBK-0001 High VoltageTerminal Block (Euro style) Note 3 900TER-0001 High Voltage Terminal Block (Barrier Style) Note 3 900TBR-0001 Low voltage Terminal Block (36 pos) Note 3 900TCK-0001 Analog Input Remote Terminal Panel (RTP) Note 6 900RTA-L001 Relay Output Remote Terminal Panel (RTP) Note 6 900RTR-H001 DI, DO, AO Remote Terminal Panel (RTP) Note 6 900RTS-0001 Low Voltage RTP Cable (1.0M, 3.28ft.) Note 6 900RTC-L010 Low Voltage RTP Cable (2.5M, 8.2ft.) Note 6 900RTC-L025 Low Votage RTP Cable (5.0M, 16.4ft.) Note 6 900RTC-L050 High Voltage RTP Cable (1.0M, 3.28ft.) Note 6 900RTC-H010 High Voltage RTP Cable (2.5M, 8.2ft.) Note 6 900RTC-H025 High Votage RTP Cable (5.0M, 16.4ft.) Note 6 900RTC-H050 LV RTP Cable (32/16 channel) (1.0M, 3.28ft) Note 6 900RTC-3210 LV RTP Cable (32/16 channel) (2.5M, 8.2ft) Note 6 900RTC-3225 LV RTP Cable (32/16 channel) (5.0M, 16.4ft) Note 6 900RTC-3250 8 ch A/O RTP Cable (1M, 3.3ft) Note 6 900RTC-B810 8 ch A/O RTP Cable (2.5M, 8.2ft) Note 6 900RTC-B825 8 ch A/O RTP Cable (5.0M, 16.4ft) Note 6 900RTC-B850 Filler Block Terminal Cover 900TNF-0001 Shield Terminal Strip (package of 2) 900TSS-0001 Terminal board jumpers (10, two pos jumpers) Note 4 900J02-0001 Terminal board jumpers (10, ten pos.jumpers) Note 4 900J10-0001 Manuals Full Document set on CD Note 2 & 7 900ME1-0060-00 Software HC Designer Config. Software CD (with Matrikon OPC Server) Note 2 & 7 900W01-0060-00 HC Utilities Software/Documentation CD Note 2 & 7 900W02-0060-00 HC Historian Software Note 2 50045756-001 Note 1: Documentation and Designer Configuration Software are not provided with this model. Please specify model numbers under Manuals and software section to order documentation and configuration software. Note 2: Documentation set and configuration software do not come along with the CPU and need to be ordered separately. Note 3: Terminal blocks for I/O modules must be ordered separately. Two styles are available for each of the two types - Euro style and Barrier style. The type of terminal block (gold and tin contacts) must be matched to the appropriate I/P board type. Note 7: Model Numbers have changed for the models below Description Old Model Numbers New 120/240VAC, 60W 900P01 -0001 900P01-0101 120/240VAC, 28W 900P02 -0001 900P02-0101 24Vdc, 60W 900P24 -0001 900P24-0101 Analog Output, 0 to 20mA, (4 channel) 900B01 -0101 900B01-0201 Pulse/Freq/Quad (4chan, 1Quad) 900K01 - 0001 900K01-0101 Full Document set on CD 900ME1-0044-44 900ME1-0060-00 Full document set, hard copy - Engish 900ME2-0044-44 900ME2-0060-00 HC Designer Config. Software CD 900W01-0044-44 900W01-0060-00 HC Utilities Software/Documentation CD 900W02-0044-44 900W02-0060-00 Note 8: Model numbers in the legacy system such as 900C31-0244-00, 900C51-0244-00, 900C71-0144-00, 900C71R-0100-44 which included the configuration software and documents have been discontinued and will not be offered with the new and SIL systems also. Documentation set and configuration software have to be ordered separately. Description Discontinued Controller C70 CPU Config. SW & Docs 900C71-0144-00 Controller C50 CPU Config.SW & Docs 900C51-0244-00 Controller C30 CPU Config. SW & Docs 900C31-0244-00 Redundant Controller Rack and CPU Controller C70R CPU Config.SW & Docs 900C71R-0100-44 51-51-16U-93 Issue 2 Page 3 of 4 Card Type Terminal Blocks Analog Input (8 channel) 900TEK-0001 900TBK-0001 Analog Output, 0 to 20mA, (4 channel) 900TEK-0001 900TBK-0001 Analog Output, 0 to 20mA, (8 channel) 900TCK-0001 Analog Output, 0 to 20mA, (16 channel) 900TCK-0001 Digital Input, Contact type, (16 channel) 900TEK-0001 900TBK-0001 Digital Input, 24VDC (16 channel) 900TEK-0001 900TBK-0001 Digital Input, 120/240 VAC, (16 channel) 900TER-0001 900TBR-0001 Digital In, 120/240VAC 125VDC (16ch Iso) 900TCK-0001 Digital Output, Relays ( 8 channel) 900TER-0001 900TBR-0001 Digital Output, 24VDC (16 Channel) 900TEK-0001 900TBK-0001 Digital Output, 120/240 VAC (8 channel) 900TER-0001 900TBR-0001 Note 4: Jumpers available for Barrier Style terminals only. Note 5: How to choose an AC Power Supply 51-51-16U-93 Issue 2 Page 4 of 4 Note 6: Using the table below, select a Remote Terminal Panel and Cable Assembly to match the module type. Module Types Module Model Remote Terminal Panel Acceptable Cables Analog Input Module 900A01 – 010X 900RTA – L001 900RTC – L010 900RTC – L025 900RTC – L050 Relay Output Module 900H01 – 010X 900RTR – H001 900 RTC – H010 900 RTC – H025 900 RTC – H050 Analog Output Module Contact Discrete Input Module DC Discrete Input Module DC Discrete Output Module 900B01 – 010X 900G01 – 010X 900G02 – 010X 900H02 – 010X 900RTS - 0001 900RTC – L010 900RTC – L025 900RTC – L050 AC Discrete Input Module AC Discrete Output Module 900G03 - 010X 900H03 – 010X 900RTS - 0001 900 RTC – H010 900 RTC – H025 900 RTC – H050 Digital Input , 32 channel Digital Output, 32 Channel Analog Input, 16 Channel 900G32-000X 900H32-000X 900A16-000X 900RTS - 0001 (2 required) 900RTC – 3225 900RTC – 3210 900RTC - 3250 Analog Output Module 8 Channel 900B08-0001 900RTS - 0001 900RTC – B810 900RTC – B825 900RTC – B850 Analog Output Module 16 Channel 900B16-0001 900RTS – 0001 (2 required) 900RTC – 3225 900RTC – 3210 900RTC - 3250 HC900 Process Control Accessories / Kits System Assemblies & Manuals Kits Part Number Spare I/O Label Kit 51452262-501 Replacement Battery Kit 51500638-501 Redundant Power, Rack Extension Kit 900RPE-0001 Replacement C30 CPU for systems built prior to 4/2006 900C32-0123-00 Replacement C50 CPU for systems built prior to 4/2006 900C52-0123-00 Replacement Scanner for systems built prior to 4/2006 900C53-0123-00 Accessories Part Number Ethernet Cable (10 feet) 51451432-010 Ethernet Cable (20 feet) 51451432-020 Ethernet Cross-over Cable (20 feet) * 51451996-020 Null Modem Cable for CPUs built before 1/2006** 51404755-501 Null Modem Cable for CPUs built after 1/ 2006** 50004820-501 250 ohm Shunt Resistor Kit (for mA ranges) (8/pkg.) 51205995-501 Industrial Ethernet Switch (8 Ports) 50008930-001 24 VDC Power Supply (1.3A) 51452041-501 24 VDC Power Supply (2.5A) 50047098-001 Manuals Part Number HC900 Controller Manual 51-52-25-107 HC900 Controller Manual, Spanish 51-52-25-107-SP HC900 Controller Manual, French 51-52-25-107-FR Designer Configuration Software Manual 51-52-25-110 Function Block Reference Guide 51-52-25-109 Communications Manual 51-52-25-111
Continue reading