Michell XTP 501 – XTP601 Oxygen Analyzers – China Supplier
If you are looking for the advanced Michell XTP501 or XTP601 Series Oxygen Analyzer, you are welcome to contact Chengdu Pudding Mechatronic Co.CPCM, one of the main air compressors and Genuine compressor spare parts distribution network in China.
Michell Oxygen Analyzers XTP501 Thermo-Paramagnetic Oxygen Analyzer
Configurable Product
|
Product Parent Code: XTP501 |
|
Fixed Configurations |
|
Feature {A} XTP501-GP1-STD1 Full HMI, Ranged 0 to 25% O2 (calibrated 0 to 21%) |
|
XTP501-GP1-STD2 Full HMI, Ranged 80 to 100% O2 |
|
Product Ordering Code {Feature A}+{Feature B}+{Feature C} |
||
|
Feature |
Item Description |
|
|
Feature {A} |
Base Model |
|
|
XTP501 Base unit |
||
|
Feature {B} |
Case & Area Class |
|
|
GP1 General Purpose Analyzer with display |
||
|
GP2 General Purpose Transmitter |
||
|
Feature {C} |
Range |
|
|
C1 |
Range 0 to 1% Oxygen |
|
|
C2 |
Range 0 to 5% Oxygen |
|
|
C3 |
Range 0 to 25% Oxygen |
|
|
C4 |
Range 20 to 100% Oxygen |
|
|
C5 |
Range 80 to 100% Oxygen |
|
|
C6 |
Range 90 to 100% Oxygen |
|
|
Feature {F} |
Cables |
|
|
F0 |
Loose connectors |
|
|
F1 |
Power & Output (5m) and loose connector |
|
|
F2 |
Power, Output & Alarm (5m) and loose connector |
|
|
F3 |
Power, Output, Alarm and Input (5m) |
|
|
Feature {X} |
Special cleaning procedure |
|
|
X3 Cleaned for O2 service (standard with enriched O2 ranges) |
||
Ordering Example
Michell XTP501-GP1+C3+F0 XTP501 with full display ranged 0 to 25% oxygen
Michell Oxygen Analyzers XTP601-GP Thermo-Paramagnetic Oxygen Analyzer
Configurable Product
|
Product Parent Code: XTP601 |
|
Fixed Configurations |
|
Supplied with Range: 0-21% in N2 Background, 50°C cell with 1/4″ NPT Gas Fittings – materials certs included. |
|
Feature {A} XTP601-GP1-C1-STD General Purpose with Viton O-ring |
|
Feature {A} XTP601-GP1-C1-SIL2 Hazardous Area analyzer with Viton O-ring + the requirements of IEC61508 SIL2 |
|
Product Ordering Code {Feature A}+{Feature B}+{Feature C}+…+{Feature F}+{Feature M} |
||
|
Feature |
Item Description |
|
|
Feature {A} |
Base Model |
|
|
XTP601 Base unit |
||
|
Feature {B} |
Case & Area Class |
|
|
GP1 General Purpose Analyzer with display |
||
|
Feature {C} |
Cell O-Ring Material |
|
|
C1 Viton |
||
|
C2 Silicone – Not for use with enriched O2 (ie > 21%) |
||
|
C3 Ekraz |
||
|
Feature {D} |
Range |
|
|
D1 |
Range 0 to 1% Oxygen |
|
|
D2 |
Range 0 to 2% Oxygen |
|
|
D3 |
Range 0 to 5% Oxygen |
|
|
D4 |
Range 0 to 10% Oxygen |
|
|
D5 |
Range 0 to 21% Oxygen |
|
|
D6 |
Range 0 to 25% Oxygen (calibrated 0 to 21%) |
|
|
D7 |
Range 0 to 50% Oxygen |
|
|
D8 |
Range 80 to 100% Oxygen |
|
|
D9 |
Range 90 to 100% Oxygen |
|
|
D10 |
Range 50 to 100% Oxygen |
|
|
D11 |
Range 0 to 4% Oxygen |
|
|
D12 |
Range 0 to 0.5% Oxygen |
|
|
D13 |
Range 20 to 100% Oxygen |
|
|
D1A |
Range 0 to 1% Oxygen (“A” suffix denotes O2 as air ingress) |
|
|
D2A |
Range 0 to 2% Oxygen (“A” suffix denotes O2 as air ingress) |
|
|
D3A |
Range 0 to 5% Oxygen (“A” suffix denotes O2 as air ingress) |
|
|
D4A |
Range 0 to 10% Oxygen (“A” suffix denotes O2 as air ingress) |
|
|
D5A |
Range 0 to 21% Oxygen (“A” suffix denotes O2 as air ingress) |
|
|
Feature {E} |
Background Gas |
|
|
E1 Nitrogen |
||
|
E2 Carbon Dioxide |
||
|
Feature {F} |
Cell temperature |
|
|
F1 Cell temp 50°C |
||
|
F3 Cell temp 60°C |
||
|
Feature {L} |
SIL rated |
|
|
L0 Standard product |
||
|
L1 Meets the requirements of IEC61508 SIL 2 |
||
|
Feature {M} |
Material Certification |
|
|
M0 No material certification |
||
|
M1 Material certificate to BS EN 10204 – type 3.1 |
||
|
Feature {X} |
Special cleaning procedure |
|
|
X3 Cleaned for O2 service (standard with enriched O2 ranges) |
||
|
X9 Product Review Required |
||
|
*Flammable mixtures are not allowed |
||
Michell XTP 601 Ordering Example
XTP601-GP1 XTP601 with full display, Silicone Cell O-Ring, 0 to 5% oxygen range, Carbon Dioxide background gas, 50°C +C2+D3+E2+F1+L0+M0 temperature, no material certificates
Michell Oxygen Analyzers XTP601-GP ACCESSORIES AND SPARE PARTS
|
Order Codes |
Product / Description |
|
PTFE-TAPE-02 |
Unsintered PTFE tape for use with enriched oxygen samples |
|
XTP601-EW24 |
Extended warranty 24 months from invoice date |
|
XTP601-EW36 |
Extended warranty 36 months from invoice date |
|
XTP601-RC |
Ribbon cable assembly |
|
XTP601-GP-HMI |
Display assembly for GP model |
|
XTP601-BLANKPLUG |
Blanking Plug |
|
XTP601-M20COMPRESS |
M20 Cable Gland (Nickel Plated Brass 20S – Compression) (GP only) |
|
XTP601-M20CONDUIT |
M20 Conduit Entry 3/4″ NPT (Nickel Plated Brass) |
|
XTP601-14198 |
GUB Lid o-ring |
|
XTP601-6371 |
Interface Plate XM |
|
XTP601-6MM |
6mm tube adapter fitting |
|
XTP601-26149 |
Fuse for main PCB |
|
XTP601-TFUSE |
Thermal Fuse (70°C) |
Oxygen Analyzers XTP601-GP Thermo-Paramagnetic Oxygen Analyzer (with HMI) – China Supplier
|
Product Parent Code: XTP601 |
||
|
Configurable Product |
||
|
Product Ordering Code {Feature A}+{Feature B}+{Feature C}+…+{Feature F}+{Feature M} |
||
|
Feature |
Item Description |
|
|
Feature {A} |
Base Model |
|
|
XTP601 Base unit |
||
|
Feature {B} |
Case & Area Class |
|
|
GP2 General Purpose Analyzer with Flame Arrestors |
||
|
Feature {C} |
Cell O-Ring Material |
|
|
C1 Viton |
||
|
C2 Silicone – Not for use with enriched O2 (ie > 21%) |
||
|
C3 Ekraz |
||
|
Feature {D} |
Range |
|
|
D1 |
Range 0 to 1% Oxygen |
|
|
D2 |
Range 0 to 2% Oxygen |
|
|
D3 |
Range 0 to 5% Oxygen |
|
|
D4 |
Range 0 to 10% Oxygen |
|
|
D5 |
Range 0 to 21% Oxygen |
|
|
D6 |
Range 0 to 25% Oxygen (calibrated 0 to 21%) |
|
|
D7 |
Range 0 to 50% Oxygen |
|
|
D8 |
Range 80 to 100% Oxygen |
|
|
D9 |
Range 90 to 100% Oxygen |
|
|
D10 |
Range 50 to 100% Oxygen |
|
|
D11 |
Range 0 to 4% Oxygen |
|
|
D12 |
Range 0 to 0.5% Oxygen |
|
|
D13 |
Range 20 to 100% Oxygen |
|
|
D1A |
Range 0 to 1% Oxygen (“A” suffix denotes O2 as air ingress) |
|
|
D2A |
Range 0 to 2% Oxygen (“A” suffix denotes O2 as air ingress) |
|
|
D3A |
Range 0 to 5% Oxygen (“A” suffix denotes O2 as air ingress) |
|
|
D4A |
Range 0 to 10% Oxygen (“A” suffix denotes O2 as air ingress) |
|
|
D5A |
Range 0 to 21% Oxygen (“A” suffix denotes O2 as air ingress) |
|
|
Feature {E} |
Background Gas |
|
|
E1 |
Nitrogen |
|
|
E2 |
Carbon Dioxide |
|
|
E3 |
Methane |
|
|
E4 |
Hydrogen |
|
|
E5 |
BIOGAS (60%CH4/40%CO2) – unless otherwise stated |
|
|
Feature {F} |
Cell temperature |
|
|
F1 Cell temp 50°C |
||
|
F3 Cell temp 60°C |
||
|
Feature {L} |
SIL rated |
|
|
L0 Standard product |
||
|
L1 Meets the requirements of IEC61508 SIL 2 |
||
|
Feature {M} |
Material Certification |
|
|
M0 No material certification |
||
|
M1 Material certificate to BS EN 10204 – type 3.1 |
||
|
Feature {X} |
Special cleaning procedure |
|
|
X3 Cleaned for O2 service (standard with enriched O2 ranges) |
||
|
X9 Product Review Required |
||
|
*For potentially flammable mixtures please consult the factory. |
||
Ordering Example
XTP601-GP2 XTP601 with flame arrestors, Silicone Cell O-Ring, 0 to 21% oxygen range (as air ingress), H2 background +C2+D5A+E4+F1+L0+M0 gas, 50°C temperature, no material certificates
Oxygen Analyzers XTP601-GP ACCESSORIES AND SPARE PARTS
|
Order Codes |
Product / Description |
|
PTFE-TAPE-02 |
Unsintered PTFE tape for use with enriched oxygen samples |
|
XTP601-EW24 |
Extended warranty 24 months from invoice date |
|
XTP601-EW36 |
Extended warranty 36 months from invoice date |
|
XTP601-RC |
Ribbon cable assembly |
|
XTP601-GP-HMI |
Display assembly for GP model |
|
XTP601-BLANKPLUG |
Blanking Plug |
|
XTP601-M20COMPRESS |
M20 Cable Gland (Nickel Plated Brass 20S – Compression) (GP only) |
|
XTP601-M20CONDUIT |
M20 Conduit Entry 3/4″ NPT (Nickel Plated Brass) |
|
XTP601-14198 |
GUB Lid o-ring |
|
XTP601-6371 |
Interface Plate XM |
|
XTP601-6MM |
6mm tube adapter fitting |
|
XTP601-26149 |
Fuse for main PCB |
|
XTP601-TFUSE |
Thermal Fuse (70°C) |
Michell Oxygen Analyzers XTP601-EX Thermo-Paramagnetic Oxygen Analyzer
|
Product Parent Code: XTP601 |
|
Fixed Configurations |
|
Supplied with Range: 0-21% in N2 Background, 50°C cell with 1/8″ NPT Gas Fittings – Materials certs included. |
|
Feature {A} XTP601-EX1-C1-STD XTP601-EX1-C2-STD XTP601-EX1-C3-STD Hazardous Area analyzer with Viton O-ring Hazardous Area analyzer with Silicone O-ring Hazardous Area analyzer with EKRAZ O-ring |
|
Supplied with Range: 0-21% in N2 Background, 50°C cell with 1/8″ NPT Gas Fittings – Materials certs included. |
|
Feature {A} XTP601-EX1-C1-SIL2 XTP601-EX1-C2-SIL2 XTP601-EX1-C3-SIL2 Hazardous Area analyzer with Viton O-ring + the requirements of IEC61508 SIL2 Hazardous Area analyzer with Silicone O-ring + the requirements of IEC61508 SIL2 Hazardous Area analyzer with EKRAZ O-ring + the requirements of IEC61508 SIL2 |
Configurable Product
|
Product Ordering Code {Feature A}+{Feature B}+{Feature C}+{Feature D}+…+{Feature K}+{Feature W} |
||
|
Feature |
Item Description |
|
|
Feature {A} |
Base Model |
|
|
XTP601 Base unit |
||
|
Feature {B} |
Case & Area Class |
|
|
EX1 Hazardous Area Analyzer with display |
||
|
Feature {C} |
Cell O-Ring Material |
|
|
C1 Viton |
||
|
C2 Silicone – Not for use with enriched O2 (ie > 21%) |
||
|
C3 Ekraz |
||
|
Feature {D} |
Range |
|
|
D1 |
Range 0 to 1% Oxygen |
|
|
D2 |
Range 0 to 2% Oxygen |
|
|
D3 |
Range 0 to 5% Oxygen |
|
|
D4 |
Range 0 to 10% Oxygen |
|
|
D5 |
Range 0 to 21% Oxygen |
|
|
D6 |
Range 0 to 25% Oxygen (calibrated 0 to 21%) |
|
|
D7 |
Range 0 to 50% Oxygen |
|
|
D8 |
Range 80 to 100% Oxygen |
|
|
D9 |
Range 90 to 100% Oxygen |
|
|
D10 |
Range 50 to 100% Oxygen |
|
|
D11 |
Range 0 to 4% Oxygen |
|
|
D12 |
Range 0 to 0.5% Oxygen |
|
|
D13 |
Range 20 to 100% Oxygen |
|
|
D1A |
Range 0 to 1% Oxygen (“A” suffix denotes O2 as air ingress) |
|
|
D2A |
Range 0 to 2% Oxygen (“A” suffix denotes O2 as air ingress) |
|
|
D3A |
Range 0 to 5% Oxygen (“A” suffix denotes O2 as air ingress) |
|
|
D4A |
Range 0 to 10% Oxygen (“A” suffix denotes O2 as air ingress) |
|
|
D5A |
Range 0 to 21% Oxygen (“A” suffix denotes O2 as air ingress) |
|
|
Feature {E} |
Background Gas |
|
|
E1 |
Nitrogen |
|
|
E2 |
Carbon Dioxide |
|
|
E3 |
Methane |
|
|
E4 |
Hydrogen |
|
|
E5 |
BIOGAS (60%CH4/40%CO2) – unless otherwise stated |
|
|
Feature {F} |
Cell temperature |
|
|
F1 Cell temp 50°C |
||
|
F3 Cell temp 60°C |
||
|
Feature {L} |
SIL rated |
|
|
L0 Standard product |
||
|
L1 Meets the requirements of IEC61508 SIL 2 |
||
|
Feature {M} |
Material Certification |
|
|
M0 No material certification |
||
|
M1 Material certificate to BS EN 10204 – type 3.1 |
||
|
Feature {W} |
Material Certification (only add if the unit is destined for Brasil) |
|
|
W1 INMETRO Certification |
||
|
Feature {X} |
Special cleaning procedure |
|
|
X3 Cleaned for O2 service (standard with enriched O2 ranges) |
||
|
X9 Product Review Required |
||
|
*For potentially flammable mixtures please consult the factory. |
||
|
** The maximum standard range for Oxygen in Hydrogen is 0 to 4%. |
||
XTP601-EX1+C2+D3+E2+ XTP601 with full display, Silicone Cell O-Ring, 0 to 5% oxygen range, Carbon Dioxide background gas, 50°C F1+L0+M0+W1 temp, no material certificates, with INMETRO certification
Oxygen Analyzers XTP601-EX ACCESSORIES AND SPARE PARTS
|
Order Codes |
Product / Description |
|
PTFE-TAPE-02 |
Unsintered PTFE tape for use with enriched oxygen samples |
|
XTP601-EW24 |
Extended warranty 24 months from invoice date |
|
XTP601-EW36 |
Extended warranty 36 months from invoice date |
|
XTP601-RC |
Ribbon cable assembly |
|
XTP601-BLANKPLUG |
Blanking Plug |
|
XTP601-EX-HMI |
Display assembly for EX model |
|
XTP601-M20BARRIER |
M20 Cable Gland (Nickel Plated Brass 20S – Barrier) |
|
XTP601-M20CONDUIT |
M20 Conduit Entry 3/4″ NPT (Nickel Plated Brass) |
|
XTP601-14198 |
GUB Lid o-ring |
|
XTP601-6371 |
Interface Plate XM |
|
XTP601-6MM |
6mm tube adapter fitting |
|
XTP601-26149 |
Fuse for main PCB |
|
XTP601-TFUSE |
Thermal Fuse (70°C) |
Please note: Michell Instruments adopts a continuous development program which sometimes necessitates specification changes without notice. Please contact us for latest version. Issue No: XTP Series Order Codes_97314_V11_UK_0321
If you need Michell Oxygen Analyzer or any other models of products such as compressed air dew point sensors, please feel free to contact China Air Compressors and Genuine Parts Supplier – Pudding Mechatronic. We will try level best to supply you any genuine products with China local amazing prices to international buyers. Please feel free to submit the “RFQ” form or email to sales@aircompressorstrade.com with the coolers parts numbers, we will answer you timely.